Trane Ductulator

The duct-sizing slide rule on the air conditioning and mechanical lists: set airflow against friction rate (or velocity) and read round duct diameter and equivalent rectangular sizes. Any 1976-or-later Ductulator is allowed in the room.

14 questions in our bank cite this reference.

Short answer

Trane Ductulator is on the Florida Air Conditioning Trade Knowledge and Mechanical Trade Knowledge approved reference lists in the 1976 or later edition. Our tab set marks 5 spots in book order, from Friction rate scale to Instructions on the back. 14 of our practice questions cite it.

On the state's approved list

The list entry this guide covers, in the printing the answer key follows. Check the cover before you tab.

  • Trane Ductulator1976 or later

    The Trane Company

    Sold through Florida exam-book stores.

Editions match the DBPR reference lists (valid January 2026 – December 2026). Last checked September 25, 2026. Every question is reviewed by a Florida-licensed contractor who holds Certified Building and Class A HVAC licenses and has passed the state General Contractor exams.

The one thing to know

Duct sizing questions on the exam are Ductulator questions: given CFM and a friction rate (commonly 0.08 to 0.1 in. w.c. per 100 ft), read the round size, then the rectangular equivalent that fits the space. Practice the dial until you can read it in seconds — it is faster than any table.

Your tab set

Florida exams allow pre-tabbed, highlighted references. Place these tabs before exam day, in book order, and tick them off here.

Print tab labels

0 of 5 tabs placed

  1. 1
    Friction rate scale

    Setting in. w.c. per 100 ft of duct; typical residential 0.08–0.1

  2. 2
    Airflow and velocity

    CFM scale, FPM scale, reading velocity for noise checks (700–900 FPM trunks, 600 FPM branches)

  3. 3
    Round diameter

    Reading the round duct size at the CFM/friction setting

  4. 4
    Rectangular equivalents

    Converting a round size to width × depth with the same friction loss

  5. 5
    Instructions on the back

    The printed example and the standard-air assumptions

Highlight the question, underline the answer

Don't just tab your books — mark them as you practice. Every time a question sends you into a reference, leave a two-part mark behind: highlight the passage the question is about, and underline the exact words that answer it. Do this through your whole question bank and the book turns into a map of the tested material — so on exam day you recognize the spot, not just the section.

  1. 1

    Highlight what the question asks about

    When you look up a practice question, highlight the sentence or table the question turns on. That block is now a visual landmark you'll spot on a fast flip.

  2. 2

    Underline the exact answer

    Inside the highlight, underline the specific number, deadline, or phrase that is the answer — with a fine-tip pen. Highlight = the topic; underline = the fact.

  3. 3

    Color-code by what trips you up

    Use one highlighter color for deadlines and numbers, another for definitions, a third for the answers you got wrong twice. Your weak spots become the brightest marks in the book.

  4. 4

    Let your tabs and marks compound

    A tab gets you to the chapter; the highlight gets you to the paragraph; the underline gets you to the answer. Built up across a full question bank, that three-layer trail is the open-book skill the exam actually tests.

The reference lists allow underlining with pen or highlighter, bar handwritten and typewritten notes in the books, and bar making any marks during the exam — so every mark goes in before you walk in, and none of them can be written notes.

Navigating under time pressure

  • Set the friction-loss arrow against the design friction rate, then read the duct diameter under the required CFM; velocity reads on the same setting.
  • Equivalent rectangular sizes are on the sliding window — hold one dimension (the ceiling space) and read the other.
  • The Ductulator is for equal-friction sizing; it does not replace equivalent-length tables for fittings or the sealing and construction rules in SMACNA.

Frequently asked questions

Which edition of Trane Ductulator does the Florida exam use?

The 1976 or later edition, per the DBPR list for the Air Conditioning Trade Knowledge and Mechanical Trade Knowledge exams. The answer key follows that printing.

How should I tab Ductulator for the exam?

Duct sizing questions on the exam are Ductulator questions: given CFM and a friction rate (commonly 0.08 to 0.1 in. w.c. per 100 ft), read the round size, then the rectangular equivalent that fits the space. Practice the dial until you can read it in seconds — it is faster than any table. Build the 5-tab set on this page before exam day, in book order, with permanent tabs that carry only the section heading; movable flags and written notes are not allowed in the exam room.

How do I find answers in Ductulator quickly?

Set the friction-loss arrow against the design friction rate, then read the duct diameter under the required CFM; velocity reads on the same setting. Equivalent rectangular sizes are on the sliding window — hold one dimension (the ceiling space) and read the other. The Ductulator is for equal-friction sizing; it does not replace equivalent-length tables for fittings or the sealing and construction rules in SMACNA.